AWA MODULA
250

AWA MODULA
500
Marzo 31, 2015
LONG LIFE STORAGE
Ottobre 9, 2015

AWA MODULA
250

Water production of 2500 l/day.
CHARACTERISTICS AWA MODULA 250-W-X
Nominal water production 2500 litres/day
Installed electrical power 60 kW (54 kW + 10%)
Nominal environment conditions 30° C & 70% R.H.
Energy consumption 0.28 kWh/litre
Cooling circuit coolant Environment friendly - R134a
Sound pressure level 75 dBA (at a distance of 10 m)
Size (W x D x H) 4950 x 2230 x 2470 mm
Weight 5000 kg
Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
X (Model) Power supply
S version 400 V + 10% / 3Ph + Ground / 50 Hz
A version 460 V+ 10% / 3Ph + Ground / 60 Hz
L version 220 V + 10% / 3Ph + Ground / 60 Hz

Other versions available on demand

 

 

The materials coming in contact with water are certified for contact with food.

CHARACTERISTICS AWA MODULA 250-HWA-X
Nominal water production 2500 litres/day
Installed electrical power 60 kW (54 kW + 10%)
Nominal environment conditions 30° C & 70% R.H.
Energy consumption 0.28 kWh/litre
Cooling circuit coolant Environment friendly - R134a
Sound pressure level 75 dBA (at a distance of 10 m)
Size (W x D x H) 4950 x 2230 x 2470 mm
Weight 5500 kg
Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
   
Available heating thermal power (Water) 120 kW – 2000 litres/hour 50° C
Available cooling thermal power (Air) 100 kW – 8000 m3/hour at 24° C 40% R.H.
X (Model) Power supply
S version 400 V + 10% / 3Ph + Ground / 50 Hz
A version 460 V+ 10% / 3Ph + Ground / 60 Hz
L version 220 V + 10% / 3Ph + Ground / 60 Hz

Other versions available on demand

 

 

The materials coming in contact with water are certified for contact with food.

CHARACTERISTICS AWA MODULA 250-HWAC-X
Nominal water production 2500 litres/day
Installed electrical power 60 kW (54 kW ± 10%)
Nominal environment conditions 30° C & 70% R.H.
Energy consumption 0.28 kWh/litre
Cooling circuit coolant Environment friendly - R134a
Sound pressure level 75 dBA (at a distance of 10 m)
Size (W x D x H) 4950 x 2230 x 2470 mm
Weight 5800 kg
Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
   
Available heating thermal power (Water) 120 kW – 2000 litres/hour 50° C
Available cooling thermal power (Air) 100 kW – 8000 m3/hour at 24° C 40% R.H.
Available cooling thermal power (Water) From 25 to 100 kW*
X (Model) Power supply
S version 400 V + 10% / 3Ph + Ground / 50 Hz
A version 460 V+ 10% / 3Ph + Ground / 60 Hz
L version 220 V + 10% / 3Ph + Ground / 60 Hz

Other versions available on demand
* depending on the water production requirement

 

 